Home | Contact Us

May I Help You? (216) 251-2510

Advanced Oil Analysis Varnish Analysis Filter Debris Analysis Service

Rust Test

ASTM method - D665

Rust preventing characteristics of oil in the presence of water.


Operating Principle. A portion of the oil is placed in a beaker along with water and a polished steel rod. The beaker is then immersed in a heated bath and is stirred for 4 hours. At the end of the 4 hours, the steel rod is inspected for the presence of rust / corrosion.

Significance. Evaluates the ability of the lubricant to prevent the corrosion of ferrous parts should water become mixed with the oil.

Application. Turbines or any other machine where there is a concern of corrosion with the presence of water.

Contact Us Regarding Your Oil Analysis Needs

We look forward to hearing from you to discuss your oil analysis needs.
> Contact Us

Same-day oil testing available!

> Click here for additional information.

Customer Login:

  • Login ID:
  • Password:



Insight Services, Inc.  20338 Progress Drive  Strongsville, OH 44149  Phone: 216-251-2510  Fax: 216-251-2515
  1. Home
  2. About Us
  3. Customer Reports
  4. Sample Reports
  5. Free Offers
  6. Tests
  7. FAQ
  8. Lube Surveys
  9. Training
  10. Contact Us

  11. ICP Spectroscopy
  12. Particle Count Testing
  13. Viscosity Testing
  14. FTIR Testing
  15. Ferrography
  16. Acid Number
  17. Oil Filter Testing
  18. Karl Fischer Water Test

  19. Lubricant Testing
  20. RPVOT
  21. Varnishing Potential
  22. Synthetic Oil Testing
  23. Filter Analysis
  24. Foam
  25. Rust
  26. Demulsibility

  27. Ferrous Wear Concentration
  28. Base Number
  29. Fuel Dilution
  30. Customer Registration