May I Help You? (216) 251-2510
> testing services > filter debris analysis > FDA technique
The FDA instrument is a self-contained unit which employs an automated method for filter washing to extract all debris from the filter with high repeatability and reproducibility. A used filter is placed in the system wash chamber and all debris is removed from the filter using a combination of fluid and pressurized air. The wash fluid carrying the filter debris passes through a MetalSCAN sensor which quantifies and sizes the amount of ferrous and non ferrous debris. The fluid then runs through a filter patch where the sample of debris is captured for further metallurgical analysis by X-ray fluorescence (XRF). XRF analysis provides the elemental composition of the sample that can be correlated to the wear debris of interest.